3″ Dual Action Manhole Brace

3″ DUAL ACTION MANHOLE BRACE

3″ Dual Action Manhole Shores – Four Sided Pit

Standard Metric

Four Sided Pit

Max Span Depth of Cut* B-Soils Depth of Cut* C-60 Soils Depth of Cut* C-80 Soils Depth of Cut* B-Soils Depth of Cut* C-60 Soils Depth of Cut* C-80 Soils
ft ft ft ft ft ft ft
4 On Center Spacing 4 On Center Spacing 4 On Center Spacing 3 On Center Spacing 3 On Center Spacing 3 On Center Spacing
7 25 25 10 25 25 10
8 25 25 10 25 25 10
9 25 25 10 25 25 10
10 25 25 10 25 25 10
11 25 25 10 25 25 10
12 25 25 10 25 25 10
13 25 24 10 25 25 10
14 25 22 10 25 25 10
15 25 20 10 25 24 10
16 23 18 10 25 22 10
17 22 17 10 25 21 10
18 20 16 10 24 19 10
19 18 15 10 22 17 10
20 17 13 10 20 16 10
21 15 12 10 18 14 10
22 14 12 10 17 13 10
23 13 11 9 16 12 10
24 12 10 9 14 11 9

*PSF (pounds per square foot) ratings indicate maximum shield capacities. Depths are based on B, C and C-80 soil types as described in OSHA’s 29 CFR Part 1926 Subpart P, October 31, 1989 with Type B not exceeding 45 PSF per foot of depth, Type C not exceeding 60 PSF per foot of depth and Type C-80 not exceeding 80 PSF per foot of depth. Determine actual soil pressure and consult manufacturers’ tabulated data prior to each use.

Job site photos are strictly intended for general product information only and may not comply with all applicable safety standards. Always refer to manufacturers’ serialized specific tabulated data, O.S.H.A. 29 CFR 1926 Subpart P for excavations and all applicable safety standards prior to each use

3″ Dual Action Manhole Shores – Two Sided Trench

Standard Metric

Two Sided Trench

Max Span Depth of Cut* B-Soils Depth of Cut* C-60 Soils Depth of Cut* C-80 Soils Depth of Cut* B-Soils Depth of Cut* C-60 Soils Depth of Cut* C-80 Soils
ft ft ft ft ft ft ft
4 On Center Spacing 4 On Center Spacing 4 On Center Spacing 3 On Center Spacing 3 On Center Spacing 3 On Center Spacing
7 25 25 10 25 25 10
8 25 25 10 25 25 10
9 25 25 10 25 25 10
10 25 25 10 25 25 10
11 25 25 10 25 25 10
12 25 25 10 25 25 10
13 25 25 10 25 25 10
14 25 25 10 25 25 10
15 25 23 10 25 25 10
16 25 21 10 25 25 10
17 25 20 10 25 24 10
18 23 18 10 25 22 10
19 21 16 10 25 20 10
20 19 15 10 23 18 10
21 18 14 10 21 17 10
22 16 13 10 20 15 10
23 15 12 10 18 14 10
24 14 12 10 17 13 10

*PSF (pounds per square foot) ratings indicate maximum shield capacities. Depths are based on B, C and C-80 soil types as described in OSHA’s 29 CFR Part 1926 Subpart P, October 31, 1989 with Type B not exceeding 45 PSF per foot of depth, Type C not exceeding 60 PSF per foot of depth and Type C-80 not exceeding 80 PSF per foot of depth. Determine actual soil pressure and consult manufacturers’ tabulated data prior to each use.

Job site photos are strictly intended for general product information only and may not comply with all applicable safety standards. Always refer to manufacturers’ serialized specific tabulated data, O.S.H.A. 29 CFR 1926 Subpart P for excavations and all applicable safety standards prior to each use

Contact Pro-Tec

    Your Name *
    Email*
    Your Company
    Zip/Postal Code
    Phone #
    Message *

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Why Pro-Tec Equipment

    why-pro-tec-location

    Pro-Tec Equipment is designed with superior quality, safety, dependability and durability in mind. We have continued to expand our range of equipment and services to ensure you, our customer, have what you need to meet the constant challenges you face at the worksite. Your success is our success.

    Learn More

    Download Product Literature

    Downloadable PDFs of our product lines.

    View All